Equipment
Lepu Medical > Product Information > Equipment > Angiography Interventional X-R..

Vicor-CV300

Interventional Angiography System










Product Features



Victor-CV300 Interventional Angiography System is independently designed and manufactured by Lepu Medical Equipment (Beijing) Co., Ltd. Victor-CV300 provides all-electric control experience and comprehensive clinical applications to satisfy with multiple interventions in surgery and interventional radiology such as cardiovascular, neurovascular and peripheral vascular diagnosis and treatments.


.  Ceiling-suspended structure with five degrees of freedom

.  Advanced images chain configuration

.  Imported X-ray tube

.  High-resolution images


Protected-movements Design

Three stages of protection ensure the safety of operation:
 

Collision Detection System. The built-in 3D model simulator is able to monitor the status of the equipment to detect the distances of components, decelerating timely to avoid collision.

 

Collision Brake System. Installed at the locations with high risk of collision. The system will automatically discontinue the movement to prevent damages.

 

Movement Limitation Protection System. Each movement is protected by primary and secondary limitation protections to prevent over travel.










Parameters


The C-arm Opening Diameter: 1900mm


Movement Range:

L-arm Rotating Range

 

-110°~110°

L-arm Longitudinal Movement

 

0~1900mm

L-arm at the Head End of Patient

LAO/RAO

135°/135°

CRAN/CAUD

50°/90°

L-arm on the Right Side of Patient

LAO/RAO

90°/50°

CRAN/CAUD

60°/60°

L-arm on the Left Side of Patient

LAO/RAO

50°/90°

CRAN/CAUD

60°/60°

Source to Image-receptor Distance (SID)

 

850mm~1150mm

 

Catheter Bed

 

 

Vertical Movement Range

 

725mm~1025mm

Longitudinal Movement Range

 

≥1200mm

Lateral Movement Range

 

-180mm~180mm

 

 










Clinical Applications















Clinical Images



Real-time image of cardiac interventional procedures


       




Real-time image of cerebral interventional procedure




Real-time image of renal vascular interventional procedure




Real-time 
subtraction angiography image of hepatic artery interventional procedure

 




Real-time subtraction angiography image of iliac invasive surgery




Real-time subtraction angiography image of renal invasive surgery

 











Contact Us



If you have any query about the product information, please contact our International Sales & Marketing Department: international@lepumedical.com


SOURCE: Lepu Medical International Sales & Marketing Department


  SITE MAP   RECRUITMENT   CONTACT US
POWERED BY LEPU MEDICAL
© Copyright  1999-2014  lepumedical.com,  All rights reserved
版权所有    乐普(北京)医疗器械股份有限公司    京ICP备13012321号