Contact Us
Lhotse Cementless Hip Replacement Implant
Lhotse Cementless Hip Replacement Implant
Lhotse Cementless Hip Replacement Implant

Lhotse Cementless Hip Replacement Implant

Cementless implant, can be used in both total and partial hip arthroplasty. 

Consists of 6 components: 

  • Femoral Stem

  • Centralizer

  • Restrictor

  • Changeable Femoral Head

  • Total Hip Poly Acetabulum

  • Bipolar Femoral Head for partial hip arthroplasty.


Lhotse Cementless Hip Replacement Implant Details 


  • Material: S5A17 Femoral Stem, Titanium Alloy with Titanium coating

  • H5C00 Changeable Femoral Head, Co-Cr-Mo Alloy

  • L5A45 Polyethylene Liner, UHMWPE

  • M5A17total hip metal cup, Titanium Alloy with Titanium coating

  • A5A10 Acetabular Cup Screw, Titanium Alloy

  • D1C50 Bipolar Femoral Head Co-Cr-Mo Alloy+ UHMWPE



S5A17 Femoral Stem1,2,3,4,5,6,7,7.5,8,8.5
H5C00 Changeable Femoral Head22/M, 22/L, 28/S, 28/M, 28/L, 28/XL
L5A45 Polyethylene Liner38/22,40/22,42/28, 44/28, 46/28, 48/28, 50/28, 52/28, 54/28
M5A17total hip metal cup38, 40, 42, 44, 46, 48, 50, 52, 54, 56, 58, 60
A5A10 Acetabular Cup ScrewΦ6.5×15, Φ6.5×20,Φ6.5×25,Φ6.5×30,Φ6.5×35,Φ6.5×40
D1C50 Bipolar Femoral HeadΦ38/22,Φ40/22, Φ42/22, Φ44/22, Φ46/28, Φ48/28, Φ50/28, Φ52/28, Φ54/28


Features & Benefits

  • *Classic design examined by long period of clinical trials.

  • *Stem and cup made by wrought titanium alloy, with excellent modular of elastic, high strength, and good biocompatibility.

  • *Plasma sprayed titanium coating with porous structure on the surface of stem and cup, facilitates in-growth of bone.

  • *Recommended head/neck ratio design, which enables better ROM (range of motion).

  • *Anti-rotation scallops for cup and polyethylene liners provide rotational stability.

  • *Optimized design, implant sizes match anatomical data.


Notes in surgery:

  • *Cement-less Hip suitable for young-aged patient whose bone has good quality.

  • *Resistance and chatter from cortical engagement may be used as a signal to cease taper reaming.

  • *Ensure sequential reaming is completed before broaching. If the broach size is countersunk more than 4mm below the neck resection, re-evaluate the resection level. If the neck resection level is determined to be correct ream up and use the next size broach.


Lhotse Cementless Hip Replacement Implant Specification

PackagingInner. Two layers of the sterile package, both are Tyvek + PETG heat-sealing package, covered by carton and heat shrinkable films
External: Standard carton
Lead Time7-21 days
Delivery≤30kg, Door to door (DHL/TNT/UPS/FEDEX/EMS, etc.)
> 30 kg, Airport to Airport
B air or by sea


Provide Total Solution For
Patients With
Cardiovascular Disease
Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.