country
Contact Us
Tibia & Fibula
Tibia & Fibula

Tibia & Fibula

LC-LCP(III) (Tibia), Mono-lock
LC-LCP(III) (Tibia), Mono-lock

Application: For fracture of tibia diaphysis

Spec.: 123mm*6 holes - 231mm*12 holes

Material: Titanium

Matching Screw: 

Φ4.5 Cortical Screw;

Φ5.0 Self-tapping Locking Screw

Distal Femoral Condylar Buttress Locking Plate (II)
Distal Femoral Condylar Buttress Locking Plate (II)

Application: For fracture of distal femur

Spec.: 98mm*3 holes - 258mm*13 holes(L,R)

Material: Titanium

Matching Screw: 

Φ4.5 Cortical Screw;

Φ5.0 Self-tapping Locking Screw

Buttress Locking Plate (T-shape)
Buttress Locking Plate (T-shape)

Application: For proximal tibia fracture

Spec.: 68mm*3 holes -180mm*10 holes(L,R)

Material: Titanium

Matching Screw: 

Φ5.0 Self-tapping Locking Screw;

Φ4.5 Cortical Screw

Buttress Locking Plate (L-shape)
Buttress Locking Plate (L-shape)

Application: For proximal tibial fracture

Spec.: 68mm*3 holes - 180mm*10 holes(L,R)

Material: Titanium

Matching screw: 

Φ5.0 Self-tapping Locking Screw;

Φ4.5 Cortical Screw

Proximal Medial Tibial Locking Plate (Golf-shape) (II), Mono-lock
Proximal Medial Tibial Locking Plate (Golf-shape) (II), Mono-lock

Application: For proximal tibial fracture

Spec.: 89mm*3 holes - 281mm*15 holes (L,R)

Material: Titanium

Matching Screw: 

Φ5.0 Self-tapping Locking Screw;

Φ4.5 Cortical Screw

Proximal Lateral Tibial Locking Plate (Golf-shape) (II), Mono-lock
Proximal Lateral Tibial Locking Plate (Golf-shape) (II), Mono-lock

Application: For proximal tibial fracture

Spec.: 97mm*3 holes - 289mm*15 holes (L,R)

Material: Titanium

Matching Screw: 

Φ5.0 Self-tapping Locking Screw;

Φ4.5 Cortical Screw

Distal Lateral Tibial Locking Plate (II)
Distal Lateral Tibial Locking Plate (II)

Application: For distal tibial fracture

Spec.: 86mm*3 holes - 246mm*13 holes (L,R)

Material: Titanium

Matching Screw: 

Φ5.0 Self-tapping Locking Screw;

Φ4.5 Cortical Screw

Distal Medial Tibial Locking Plate (II), Mono-lock
Distal Medial Tibial Locking Plate (II), Mono-lock

Application: For fracture of medial distal tibia

Spec.: 86*3 holes - 246*13 holes (L, R)

Material: Titanium

Matching Screw: 

Φ5.0 Self-tapping Locking Screw;

Φ4.5 Cortical screw

Distal Medial Tibial Locking Plate (III), Mono-lock
Distal Medial Tibial Locking Plate (III), Mono-lock

Application: For fracture of distal medial tibia

Spec.: 128mm*4 holes - 240mm*11 holes (L,R)

Material: Titanium

Matching Screw: 

Φ3.5 Self-tapping Locking Screw;

Φ3.5 Cortical Screw

Distal Lateral Fibular Locking Plate (II)
Distal Lateral Fibular Locking Plate (II)

Application: For fracture of distal lateral fibula

Spec.: 55mm*2 holes- 151mm*10 holes (L,R)

Material: Titanium

Matching screw: 

Φ3.5 Self-tapping Locking Screw;

Φ3.5 Cortical Screw

Provide Comprehensive Solution For
Global Patients
Fill out the form to leave inquiries. We would get back to you as soon as possible.