Contact Us
Tibia & Fibula
Tibia & Fibula

Tibia & Fibula

LC-LCP(III) (Tibia), Mono-lock
LC-LCP(III) (Tibia), Mono-lock

Application: For fracture of tibia diaphysis

Spec.: 123 mm*6 holes -231mm*12 holes

Material: Titanium

Matching Screw: 4.5 Cortical Screw;

5.0 Self-tapping Locking Screw;

Distal Femoral Condylar Buttress Locking Plate (II)
Distal Femoral Condylar Buttress Locking Plate (II)

Application: For fracture of distal femur

Spec.: 98 mm*3 holes -258mm*13 holes(L, R)

Material: Titanium

Matching Screw: 4.5 Cortical Screw;

5.0 Self-tapping Locking Screw;

Buttress Locking Plate (T-shape)
Buttress Locking Plate (T-shape)

Application: For proximal tibia fracture

Spec.: 68 mm*3 holes -180mm* 10 holes(L, R)

Material: Titanium

Matching Screw: 5.0 Self-tapping Locking Screw;

4.5 Cortical Screw;

Buttress Locking Plate (L-shape)
Buttress Locking Plate (L-shape)

Application: For proximal tibial fracture

Spec.: 68 mm*3 holes -180mm* 10 holes(L,R)

Material: Titanium

Matching screw: 5.0 Self-tapping Locking Screw;

4.5 Cortical Screw;

Proximal Medial Tibial Locking Plate (Golf-shape) (II), Mono-lock
Proximal Medial Tibial Locking Plate (Golf-shape) (II), Mono-lock

Application: For proximal tibial fracture

Spec.: 89mm*3 holes -281mm* 15 holes (L,R)

Material: Titanium

Matching Screw: 5.0 Self-tapping Locking Screw;

4.5 Cortical Screw;

Proximal Lateral Tibial Locking Plate (Golf-shape) (II), Mono-lock
Proximal Lateral Tibial Locking Plate (Golf-shape) (II), Mono-lock

Application: For proximal tibial fracture

Spec.: 97 mm*3 holes -289mm* 15 holes (L,R)

Material: Titanium

Matching Screw: 5.0 Self-tapping Locking Screw;

4.5 Cortical Screw;

Distal Lateral Tibial Locking Plate (II)
Distal Lateral Tibial Locking Plate (II)

Application: For distal tibial fracture

Spec.: 86 mm*3 holes -246mm* 13 holes (L,R)

Material: Titanium

Matching Screw: 5.0 Self-tapping Locking Screw;

4.5 Cortical Screw;

Distal Medial Tibial Locking Plate (II), Mono-lock
Distal Medial Tibial Locking Plate (II), Mono-lock

Application: For fracture of medial distal tibia

Spec.: 86*3 holes - 246*13 (L, R)

Material: Titanium

Matching Screw: 5.0 Self-tapping Locking Screw;

4.5 Cortical screw;

Distal Medial Tibial Locking Plate (III), Mono-lock
Distal Medial Tibial Locking Plate (III), Mono-lock

Application: For fracture of distal medial tibia

Spec.: 128 mm*4 holes -240mm* 11 holes (L, R)

Material: Titanium

Matching Screw: 3.5 Self-tapping Locking Screw;

3.5 Cortical Screw;

Distal Lateral Fibular Locking Plate (II)
Distal Lateral Fibular Locking Plate (II)

Application: For fracture of distal lateral fibula

Spec.: 55 mm*2 holes-151 mm*10 holes (L, R)

Material: Titanium

Matching screw: 3.5 Self-tapping Locking Screw;

3.5 Cortical Screw;

Provide Comprehensive Solution For
Global Patients
Fill out the form to leave inquiries. We would get back to you as soon as possible.