Vicor-CV Robin C/F DSA(Digital Subtraction Angiography) System is a ceiling-suspended and floor-mounted angiography system independently developed by Lepu Medical Equipment (Beiing) Co., Ltd. based on a new digital flat panel detector.
HD images, showing full details
Concentrated on the user's concerns, it makes lesions have nowhere to hide
Safety protection to safeguard physicians and patients
Intelligent radiation dose control and triple motion protection, to safeguard the safety of both physicians and patients
Continuous operation and stable performance
X-ray tube with high heat capacity, to fully meet the needs for interventional diagnosis and treatment
Convenient and efficient operation
Humanized design makes the operation fast and efficient
Flexible choice as needed
Flat-panel detectors with different configurations
30x30/30x40 compatible dimensions, easy to perform the interventional surgery for the whole body
154µm/194µm pixel, flexibly selected according to customer's needs
Ideal choice for primary medical care (G-1592)
Stable operation at high power and load, strong
16-bit super HD display, to effectively improve the dynamic range
Multi-field full coverage
Bulb tube with individualized configuration
environmental adaptability and easy maintenance, especially suitable for primary medical care.
Choice for diverse needs (EX79039)
A grid-controlled technology to eliminate the glow and afterglow and effectively reduce the radiation dose. Liquid metal lubricated bearing continuously rotates at high speed, to capture images without time delay. With ultra-large heat capacity, it can meet the needs for complex interventional surgery.
Vicor-CV Robin C
Vicor-CV Robin F
64-bit Chinese interface, providing user-friendly interactive interface
Accelerated real-time processing module with efficient GPU, and stable and reliable image
Supporting multiple image processing tools such as automatic measurement, ventricular analysis and QCA analysis
Real-time function of virtual beam limiter, helpful to reduce scattered rays and improve the safety of both physicians and patients
Radiation dose report in compliance with IEC standard
Safety design in compliance with IHE equipment connectivity and network safety standard
Data transmission in compliance with DICOM3.0 and related standards
Supporting data storage and migration management
Efficient completion of vascular contour and morphological data analysis, and generation of QCA analysis report
Supporting dynamic correction of stent position to enhance stent visualization
Full-automatic seamless image splicing to expand diagnostic coverage and clearly display limb details
In full consideration of the different needs in different hospital installation sites, the fourth-generation Vicor-CV Robin C (ceiling-mounted)ZF (floor-mounted) medical X-ray angiography equipment is provided with a more stable motion system; since it is flexibly and conveniently operated, it can improve the operation efficiency.
Isocentric C-shaped arm
Flexible control and intelligent lesion locking
Intelligent catheter bed
Supporting step function, and meeting the needs of step imaging of lower limbs
ECG control interface
Easy to use
The control console is functionally clear with all control functions
Intelligent control system conforms to ergonomics and is convenient to operate
Multi-axis combined motion, full coverage
With the distributed motion control system, it can realize accurate and stable motion
Multi-axis combined motion is helpful to improve the clinical efficiency
As an image recognition technique, it is used to realize the motion compensation for the X-ray image to clearly and accurately display the fine structure of the stent and help physicians immediately evaluate the release of the stent during the operation.
• This feature requires detailed consultation with sales
Deep learning can be used to divide and reconstruct the coronary artery CTA, calculate the fractional flow reserve (FFR), and help physicians evaluate patients' functional myocardial ischemia.
• This feature requires detailed consultation with sales
With the perfect 3D reconstruction function, VCV-Swift supports reconstruction techniques such as volume reconstruction (VR), multiplanar reconstruction (MPR), maximum intensity projection (MIP), and minimum intensity projection (MINIP). It has great advantages in analyzing the three-dimensional morphology and spatial relationship of blood vessels, and has great diagnostic value in interventional therapy for vascular system diseases, tumors, etc.:
1. It can avoid vascular structure overlapping, to make vascular images clearer and more accurate.
2. The three-dimensional relationship and tubal lumen structure between lesion sites and other normal tissues and organs can be observed at any angle.
3. The dosage of contrast agent, the time of diagnosis and treatment and surgery, and the exposure dose can be reduced.
4. Accurate measurement results can provide data for surgery and interventional treatment.
*Product registration and availability vary by country. For more information on product availability, please contact us here.