- Coronary Stents Coronary Balloons Catheters Guide Wires Introducer Sheaths Accessories Peripheral Interventional Products
- Immunoassay Molecular Diagnostics Hematology Diagnostics POCT Lab Solution
- Structural Heart Diseases Products
- Vascular Access Blood Pressure Transducer Arterial Blood Sampler CVC Accessories IV Catheter Needle-free Connectors Insulin Injection Pain Relief
- Hemodialysis consumables Hemoperfusion Cartridge Dialysis machine
- ECG Patient Monitor Oximeter
- Cardiovasculars Oncology Anti-infectives Central Nervous System Others
- Endoscope Endoscopic Ultrasound System
- Trauma Implant Spinal Implant Artificial Joint Sports Medicine
- Pacemakers and Leads Equipments
- ELISA CLIA FIA
- Nucleic Acid Extraction Nucleic Acid Extraction & PCR Kits Real-Time PCR
- Thrombelastography Analyzer Blood Grouping Platelet Aggregation
- POCT - FIA Colloidal Gold
- NeoECG Holter Monitor Portable ECG Monitor AI-ECG Pocket ECG
- Patient Monitor Vital Signs Monitor End-tidal Capnography
- Fingertip Oximeter Handheld Oximeter Wrist Oximeter Wearable Oximeter All-in-One Health Monitor POCT Solution
- OBS Locking Compression Plate Locking Plates Conventional Plates Mini Plates System Screws Patella Ring - Patented Product Metal Pins Cable System
- Internal Fixation System Laminoplasty Plate System Percutaneous Kyphoplasty Fusion Cage Cervical Fixation System
- Hip System Knee System
- Suture Anchor Suture Button
Vesscide Cutting Balloon Dilatation Catheter
- Performance Tips
- Structure Indication and Technical Parameters
-
Can be Expanded Repeatedly, Do not Reverse the Catheter Between Two Expansions
-
Structure Indication and Technical Parameters
1. Adapted guiding catheter: Minimum guiding catheter 1.8mm/6F2. Adapted guiding wire:0.36mm/0.014inch3. Effective length of the catheter:1350mm4. Marker location:Both ends of the balloon
The Vesscide Cutting Balloon Dilatation Catheter is intended for use in the treatment of coronary artery stenosis. The target lesion should possess the following characteristics:
(1) Localized lesions with lesion length ≤ 20mm.
(2) Reference vessel diameter (RVD) of 2.00 mm to 4.00 mm
(3) Readily accessible to the device
(4) Light to moderate tortuosity of proximal vessel segment
(5) Non-angulated lesion segment (< 45° )
(6) Smooth angiographic contour
(7) Absence of angiographically visible thrombus.
This product is presented for academic exchange purpose only and is not intended for sale within European Union.
Thank You for Your Attention on Lepu Medical!
Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.