Products
IFU
LEPU Medical
LEPU Medical
Vesscide Cutting Balloon System

Vesscide Cutting Balloon System

Vesscide Cutting Balloon System
Vesscide Cutting Balloon System
Enquire Now
Product Details
  • Performance Tips
  • Structure Indication and Technical Parameters
  • Can be Expanded Repeatedly, Do not Reverse the Catheter Between Two Expansions
    e Can be Expanded Repeatedly, Do not Reverse the Catheter Between Two Expansions
  • Structure Indication and Technical Parameters
    Structure Indication and Technical Parameters 1. Adapted guiding catheter Minimum guiding catheter 1...
    1. Adapted guiding catheter: Minimum guiding catheter 1.8mm/6F
    2. Adapted guiding wire:0.36mm/0.014inch
    3. Effective length of the catheter:1350mm
    4. Marker location:Both ends of the balloon
Ordering Information
Ordering Information Indications
Indications

The Vesscide Cutting Balloon Dilatation Catheter is intended for use in the treatment of coronary artery stenosis. The target lesion should possess the following characteristics:

(1) Localized lesions with lesion length ≤ 20mm.

(2) Reference vessel diameter (RVD) of 2.00 mm to 4.00 mm

(3) Readily accessible to the device

(4) Light to moderate tortuosity of proximal vessel segment

(5) Non-angulated lesion segment (< 45° )

(6) Smooth angiographic contour

(7) Absence of angiographically visible thrombus.

Product features
is Product features Segm
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
  • Blades Working height is only 0.13mm, which could avoid blood vessel perforation
  • Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
  • Blades Working height is only 0.13mm, which could avoid blood vessel perforation
  • Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Why choose Vesscide?
Why choose Vesscide?

Balloon Compliance
Balloon Compliance This product is presented for academic exchange purpose only and is not intended ...

This product is presented for academic exchange purpose only and is not intended for sale within European Union.

Thank You for Your Attention on Lepu Medical!

Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.

Submit