Products
Cardiovascular & Peripheral Products
In Vitro Diagnosis
Structural Heart Diseases Products
Critical Care Products
Hemodialysis Products
ECG & Patient Monitor & Telehealth Solutions
Pharmaceutical (API) Products
Surgical Products
Orthopedic Products
Cardiac Rhythm Management Products
Skin Care
Digital Subtraction Angiography Systems
- Coronary Stents Coronary Balloons Catheters Guide Wires Introducer Sheaths Accessories Peripheral Interventional Products
- Immunoassay Molecular Diagnostics Hematology Diagnostics POCT Lab Solution
- Structural Heart Diseases Products
- Vascular Access Blood Pressure Transducer Arterial Blood Sampler CVC Accessories IV Catheter Needle-free Connectors Insulin Injection Pain Relief
- Hemodialysis consumables Hemoperfutor Dialysis machine
- ECG Patient Monitor Oximeter
- Cardiovasculars Oncology Anti-infectives Central Nervous System Others
- Surgical Staplers Endoscopy Endoscopic Ultrasound System
- Trauma Implant Spinal Implant Artificial Joint Sports Medicine
- Pacemakers and Leads Equipments
- ELISA CLIA FIA
- Nucleic Acid Extraction Nucleic Acid Extraction & PCR Kits Real-Time PCR
- Thrombelastography Analyzer Blood Grouping Platelet Aggregation
- POCT - FIA Colloidal Gold Blood Glucose Cholesterol SARS-CoV-2
- NeoECG Holter Monitor Portable ECG Monitor OmniECG AI-ECG Pocket ECG
- Patient Monitor Vital Signs Monitor End-tidal Capnography
- Fingertip Oximeter Handheld Oximeter Wrist Oximeter Wearable Oximeter All-in-One Health Monitor POCT Solution
- OBS Locking Compression Plate Locking Plates Conventional Plates Mini Plates System Screws Patella Ring - Patented Product Metal Pins Cable System
- Internal Fixation System Laminoplasty Plate System Percutaneous Kyphoplasty
- Hip System Knee System
- Suture Anchor Suture Button
Dual Chamber Pacing System Analyzer
Dual chamber pacing System Analyzer application is used to assess electrical performance and placement of cardiac lead systems during implant of cardiac rhythm management devices
Pacing System Analysis
10 types of testing modes
One-key test design
High precision of pacing threshold testing
Exact adjustments of pacing parameters
Real-time ECG
Pacemaker Testing
One-key test of pacemaker basic parameters
Global waveforms of sensitivity test
Built-in printer, self-check and self-test are available
Technical Parameters
| Parameter | Range | Step |
| Basic Rate (ppm) | 31-180 (Dual chamber 31-90) | 1 |
| Pacing Interval (ms) | 333-1935 (Dual chamber 667-1935) | 1 |
| Max. Rate Limitation (ppm) | 100-180 (Only for dual-chamber DDD/VDD) | 1 |
| Pulse Amplitude (V) | 0.10-10.0 | 0.1 |
| Pulse Width (ms) | 0.05-2.50 | 0.01 |
| Sensing Sensitivity (mV) | 0.5-10.0 | 0.25 |
| Refractory Period (ms) | 200-500 | 25 |
| A-V Interval (ms) | 50-300 (Only for dual-chamber pacing mode) | 1 |
| Hysteresis (ms) | 0-400 | 1 |
| Quick Stimulate Rate (ppm) | 31-800 (Dual chamber 31-350) | 1 |
| Pacing Mode | VVI/VVT/VOO/ AAI/AAT | / |
| AOO/DDD/DVI/DOO/VDD |
Ordering Information
| Catalogue No. | QM2352A |
Notice: Please contact the sales for detailed information before placing the order.