AIView V10/V12 Patient Monitor
AIView V10/V12 Patient Monitor

AIView V10/V12 Patient Monitor

In-Hospital Use

Please note: this product is currently not authorized for sale or distribution in the U.S. It's strictly forbidden to advertise, marketing and resell to any U.S. customers or U.S. territories.

AIView V10/V12 Patient Monitor Details

AIView V10/V12 Features

• Full-screen design, capacitive projection touch screen, support gesture operation.

• Updated UI interface, preset H1 menu, optimized user experience, IPX2 waterproof.

• 3/5/6/10 electrodes ECG collection, ST wave filter mode, myocardial ischemia assessment, optional embedded AI chip, multi-leads simultaneous analysis.

• Multiple application scenarios, experience new monitoring concept. 


AIView V10 V12 Patient Monitor


AIView V10/V12 Work Station Scenario

• AI real-time alarm in the local system;  

• Remote AI real-time alarm via the cloud;  

• 12-lead resting ECG Analysis Report;  

• Holter ECG Analysis Report;  

• Ambulatory Blood Pressure Analysis Report;  

• ADT patient information acquisition, HIS interconnection

 

AIView Patient Monitor


Technical Specifications V12

Technical Specifications V10

ECGMeasurement range15bpm~350bpm
Measurement accuracy±1% or ±1 bpm, whichever is greater
Waveform sweeping speed6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s, error: ≤ ±5%
RESPMeasurement methodThoracic impedance
Respiration rate measurement range

Adult: 0 rpm~120 rpm

Pediatric and neonate: 0 rpm~150 rpm

Respiration rate measurement accuracy

7~120 rpm: ±2 rpm or ±2%, whichever is greater

0~6 rpm: not defined

TEMPMeasuring range0°C~50°C (32°F~122°F)
Measuring accuracy

Within the range of 1°C~50°C, the maximum allowable

error is ±0.1°C

SPO2Measurement range0%~100%
Measurement accuracy

70%~100%: ±2%

50%~69%: ±3%

0%~49%: not defined

PR measurement range30bpm~250bpm
PR measurement accuracy±2bpm or ±2%, whichever is greater
NIBPMeasurement methodMANU, AUTO, STAT, Series
Measurement range0 mmHg~300 mmHg (0.0 kPa~40.0 kPa)
Measurement accuracy±3 mmHg (±0.4 kPa)
IBPMeasurement range-50mmHg~ 300mmHg (-6.7kPa~ 40.0kPa)
Measurement accuracy±3mmHg(±0.4kPa)
Resolution1mmHg (0.1kPa)

ETCO2


Measurement modeSidestream and mainstream
Measurement range0 mmHg~150 mmHg (0 kPa~20.0 kPa)
Measurement accuracy

0 mmHg~40 mmHg (0 kPa~5.3 kPa), the error is ±2 mmHg (±0.26 kPa)

41 mmHg~70 mmHg (5.5 kPa~9.3 kPa), the error is ±5%

71 mmHg~100 mmHg (9.4 kPa~13.3 kPa), the error is ±8%

101 mmHg~150 mmHg (13.4 kPa~20.0 kPa), the error is ±10%

Other specificationBuilt-in lithium battery

10.95 V / 2750 mAh

10.95 V / 5500 mAh (option)

Display13.3 inch TFT display
Standard configurationECG, Respiration, SpO2, PR, NIBP, Temperature
Options2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, WIFI, AI Module







ECGMeasurement range15bpm~350bpm
Measurement accuracy±1% or ±1 bpm, whichever is greater
Waveform sweeping speed6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s, error: ≤ ±5%
RESPMeasurement methodThoracic impedance
Respiration rate measurement range

Adult: 0 rpm~120 rpm

Pediatric and neonate: 0 rpm~150 rpm

Respiration rate measurement accuracy

7~120 rpm: ±2 rpm or ±2%, whichever is greater

0~6 rpm: not defined

TEMPMeasuring range0°C~50°C (32°F~122°F)
Measuring accuracy

Within the range of 1°C~50°C, the maximum allowable

error is ±0.1°C

SPO2Measurement range0%~100%
Measurement accuracy

70%~100%: ±2%

50%~69%: ±3%

0%~49%: not defined

PR measurement range30bpm~250bpm
PR measurement accuracy±2bpm or ±2%, whichever is greater
NIBPMeasurement methodMANU, AUTO, STAT, Series
Measurement range0 mmHg~300 mmHg (0.0 kPa~40.0 kPa)
Measurement accuracy±3 mmHg (±0.4 kPa)
IBPMeasurement range-50mmHg~ 300mmHg (-6.7kPa~ 40.0kPa)
Measurement accuracy±3mmHg(±0.4kPa)
Resolution1mmHg (0.1kPa)
ETCO2Measurement modeSidestream and mainstream
Measurement range0 mmHg~150 mmHg (0 kPa~20.0 kPa)
Measurement accuracy

0 mmHg~40 mmHg (0 kPa~5.3 kPa), the error is ±2 mmHg (±0.26 kPa)

41 mmHg~70 mmHg (5.5 kPa~9.3 kPa), the error is ±5%

71 mmHg~100 mmHg (9.4 kPa~13.3 kPa), the error is ±8%

101 mmHg~150 mmHg (13.4 kPa~20.0 kPa), the error is ±10%

Other specificationBuilt-in lithium battery

10.95 V / 2750 mAh

10.95 V / 5500 mAh (option)

Display11.6 inch TFT display


Standard configuration
ECG, Respiration, SpO2, PR, NIBP, Temperature
Options2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, WIFI, AI Module