Products
IFU
LEPU Medical
LEPU Medical
Vesselin Drug Coated Coronary Balloon Catheter

Vesselin Drug Coated Coronary Balloon Catheter

Vesselin Drug Coated Coronary Balloon Catheter
Vesselin Drug Coated Coronary Balloon Catheter
Enquire Now
Product Details
  • Structure indication and technical parameters
  • x swipercontainerfade swipercontainerinitialized swipercontainerhorizontal 1. The effective length o...
    1. The effective length of the cathetor: 135cm
    2. The compatible guidewire: 0.014'' inch
Antiproliferative drugs
v Antiproliferative drugs Paclitaxel highly lipophilicity, long halflife, rapid absorption
  1. Paclitaxel: highly lipophilicity, long half-life, rapid absorption. long-lasting efficacy
  2. Drug concentration:3 ug/mm
  3. Drug loading matrix:

    - Urea: natural non-toxic, high hydrophilicity, rapid metabolism in the human body, promotion of rapid drug release

  4. Development mark:

    - Platinum Marker, one at each end of the balloon

  5. Delivery system:

    - New generation of rapid-exchange balloon catheter

Indications
  • classswiperwrapper forview styletransform translate3d0px, 0px, 0px transitionduration 0ms Stent Rest...
    Stent Restenosis
  • fanyiStent Restenosis Small Vascular Disease
    Small Vascular Disease
  • or datafanyifanyiSmall Vascular Disease Bifurcation Lesion
    Bifurcation Lesion
How it works
Product features
ssvideosrc2 Product features
Drug Coating
  • Coating with Active Pharmaceutical Ingredients grade urea, provide better biocompatibility, facilitate drug releasing effectively. Drug release rate in vivo achieves more than 90%.
  • Suitable particle size at 2-3um enables long term efficacy and low embolism risk
Drug
  • Paclitaxel loaded with drug dose at 3ug/mm2, inhibits restenosis continuously
Materials
  • Improved PEBAX material, lower crossing profile guarantees higher flexibility and enhanced crossability
Delivery System
  • Spiral cut hypotube design,strengthens the transition section, brings optimized deliver-ability for transition.
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
  • Blades Working height is only 0.13mm, which could avoid blood vessel perforation
  • Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
action Efficient Drug Release, Stable and Firm Coating
Efficient Drug Release, Stable and Firm Coating

1. Before balloon dilatation, about 98% of paclitaxel can reach the lesion site.

2.During balloon dilatation, about 90% of paclitaxel is effectively released.

Balloon Compliance
Balloon Compliance Ordering Information
Ordering Information
class title Ordering Information

Thank You for Your Attention on Lepu Medical!

Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.

Submit
Submit