Patient Monitor
10-inch high resolution touch screen with multiple display modes
Standard Parameters: 3/5lead ECG, RESP, SpO2, PR, NIBP, TEMP
Optional Parameters: 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, Cardiac Output, Cerebral
20 types of arrhythmia and S-T segment analysis
2-year warranty on the main unit and half year warranty on accessories
• 10.4" high-resolution display Touch screen optional
• 9 traces on-screen waveforms and maximal up to 13
• User customized NIBP measuring cycles up to 5-phase
• Data export and software upgrade for patient monitor testing
• Versatile clinical calculations for application convenience
• HL7 protocol, Bed to bed view and 5-lead ECG available
Catalogue No. | K10 |
ECG | Input dynamic range | ±(0.5mVp~5mVp) |
Differential input impedance | ≥10MΩ | |
Bandwidth | 0.05~150Hz (Diagnostic) | |
0.5~40Hz (Monitoring) | ||
1~20Hz (Operation) | ||
CMRR | ≥90dB (Diagnostic) | |
≥105dB (Monitoring & Operation) | ||
Sensitivity selection | ×1/4, ×1/2, ×1, ×2, ×4 and Auto | |
Sweeping speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s | |
HR measuring range | 15~350bpm | |
HR accuracy | ±1% or ±2bpm, whichever is greater | |
Pacemaker pulse detection and rejection function | ||
RESP | Measuring range | 0~120rpm |
Measuring accuracy | ±5% or ±2 rpm, whichever is greater | |
NIBP | Technique | Oscillometric method |
Typical measurement time | <30 seconds (adult cuff) | |
NIBP measuring range | SYS:40~275mmHg (Adult) | |
40~200mmHg (Pediatric) | ||
40~135mmHg (Neonate) | ||
NIBP measuring range | DIA:10~210mmHg (Adult) | |
10~150mmHg (Pediatric) | ||
10~95mmHg (Neonate) | ||
NIBP measuring range | MAP:20~230mmHg (Adult) | |
20~165mmHg (Pediatric) | ||
20~110mmHg (Neonate) | ||
NIBP measuring accuracy | Mean difference:±5mmHg | |
Standard deviation:8mmHg | ||
NIBP measurement mode | Manual, Auto, STAT, Multi-cycle mode | |
Auto measuring intervals | 1-480min | |
SpO2 | Technique | Dual-wavelength optical method |
Measuring range | 0%~100% | |
Measuring accuracy | Arms is not greater than 2% forSpO2 range 70~100%. | |
PR measuring range | 30~250bpm | |
PR measuring accuracy | ±2bpm or ±2%, whichever is greater | |
Low perfusion performance | As low as 0.3%. | |
CO2 | Technique | Infrared optical method |
Sampling mode | Sidestream or Mainstream | |
Measuring range | 0~150mmHg | |
Measuring accuracy | 0~40mmHg ±2mmHg | |
41~70mmHg ±5% of reading | ||
71~100mmHg ±8% of reading | ||
101~150mmHg ±10% of reading | ||
Flow rate | 50ml/min ±10 ml/min (Sidestream) | |
IBP | Technique | Strain gauge transducer |
Input sensitivity | 5µV/V/mmHg | |
Measuring range | -50~300mmHg | |
Measuring accuracy | ±2% or ±4mmHg, whichever is greater | |
Measuring positions | ART, RAP, PA, LAP, CVP | |
ICP, AUXP1, AUXP2 | ||
Calibration | zero calibrating | |
TEMP | Measuring range | 21.0~50.0℃ |
Measuring accuracy | ±0.2℃ from 25~45℃ | |
Other Specifications | Power supply | AC 100V-240V, 50/60Hz, 60VA |
Built-in lithium battery | 11.1V/4400mAh | |
Display | 10.4 inch TFT display | |
Alarming method | 3 levels audible-visible alarm | |
Networking | Ethernet | |
Standard configuration | ECG, Respiration, SpO2, PR, NIBP, Temperature | |
Option | Touch Screen, 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, Cerebral State Monitoring, Central Monitor Station |