12.1-inch high-resolution touch screen with multiple display modes

Standard Parameters: 3/5lead ECG, RESP, SpO2, PR, NIBP, TEMP

Optional Parameters: 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, Cardiac Output, Cerebral

20 types of arrhythmia and S-T segment analysis

2-year warranty on the main unit and half year warranty on accessories


K12 Patient Monitor Details

K12 Features

• 12.1" high-resolution display Touch screen optional

• 9 traces on-screen waveforms and maximal up to 13

• User customized NIBP measuring cycles up to 5-phase

• Data export and software upgrade

• Versatile clinical calculations for application convenience

• HL7 protocol, Bed to bed view and 5-lead ECG available 




Technical Specifications

Ordering Information

ECGInput dynamic range±(0.5mVp~5mVp)
Differential input impedance≥10MΩ
Bandwidth0.05~150Hz (Diagnostic)
0.5~40Hz (Monitoring)
1~20Hz (Operation)
CMRR≥90dB (Diagnostic)
≥105dB (Monitoring & Operation)
Sensitivity selection×1/4, ×1/2, ×1, ×2, ×4 and Auto
Sweeping speed6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
HR measuring range15~350bpm
HR accuracy±1% or ±2bpm, whichever is greater
Pacemaker pulse detection and rejection function
RESPMeasuring range0~120rpm
Measuring accuracy±5% or ±2 rpm, whichever is greater
NIBPTechniqueOscillometric method
Typical measurement time<30 seconds (adult cuff)
NIBP measuring rangeSYS: 40~275mmHg (Adult)
40~200mmHg (Pediatric)
40~135mmHg (Neonate)
NIBP measuring rangeDIA: 10~210mmHg (Adult)
10~150mmHg (Pediatric)
10~95mmHg (Neonate)
NIBP measuring rangeMAP: 20~230mmHg (Adult)
20~165mmHg (Pediatric)
20~110mmHg (Neonate)
NIBP measuring accuracyMean difference: ±5mmHg
Standard deviation: 8mmHg
NIBP measurement modeManual, Auto, STAT, Multi-cycle mode
Auto measuring intervals1-480min
SpO2TechniqueDual-wavelength optical method
Measuring range0%~100%
Measuring accuracyArms is not greater than 2% for SpO2 range 70~100%.
PR measuring range30~250bpm
PR measuring accuracy±2bpm or ±2%, whichever is greater
Low perfusion performanceAs low as 0.3%.
Cerebral State Monitoring (CSM)EEG sensitivity±400µV
Noise level<2µVp-p, <0.4µV rms (1~250Hz)
CMRR>140dB
Input impedance>50Mohm
CSI and update0-100. filter: 6-42Hz, 1 sec. update
EMG%0-100 (logarithmic), filter: 75-85 Hz, 1 sec. update
BS%0-100. filter: 2-42 Hz, 1 sec. update
IBPTechniqueStrain gauge transducer
Input sensitivity5µV/V/mmHg
Measuring range-50~300mmHg
Measuring accuracy±2% or ±4mmHg, whichever is greater
Measuring positionsART, RAP, PA, LAP, CVP
ICP, AUXP1, AUXP2
Calibrationzero calibrating
Cardiac Output (C.O.)Blood temperature23-43℃, accuracy: ±0.5℃

measuring: range

Injecta temperature0-20℃, accuracy: ±0.5℃

measuring: range

Measuring range0.2~20 L/min

Measuring accuracy±0.2 L/min or ±10%, whichever is greater
Other SpecificationsPower supplyAC 100V-240V, 50/60Hz, 60VA
Built-in lithium battery11.1V/4400mAh
Display12.1 inch TFT display
Alarming method3 levels audible-visible alarm
NetworkingEthernet
Standard configurationECG, Respiration, SpO2, PR, NIBP, Temperature
Option2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG Cardiac Output, Cerebral State Monitoring, CMS, Touch Screen


Catalogue No.K12