country
Contact Us
Superview-12 Modular Monitor
Superview-12 Modular Monitor

Superview-12 Modular Monitor

Modular Monitor

12.1 inch high-resolution TFT display with LED backlight

Standard Parameters: 3/5lead ECG, RESP, SpO2, PR, NIBP, TEMP

Optional Parameters: 2-IBP, EtCO2, SunTech NIBP, CO, CSM, Multi-gas

ARR & S-T Segment Analyze

Adult/Pediatric/Neonate measurement modes

2-year warranty on the main unit and half year warranty on accessories


Superview-12 Modular Monitor Details

Superview-12 Features

• 12.1" high-resolution TFT display with LED backlight

• Arrhythmia analysis and S-T segment measurement

• Protection against defibrillator discharge

• Adult/Pediatric/Neonate measurement modes

• Visual and audible alarm; Networking capability

• Up to 9 waveforms simultaneously display

• 140-hour ECG waveform data storage and recall

• 2000-hour data trends with a graphic and tabular view

• 2000 groups event, ARR and SpO2 storage

• Built-in lithium battery; Touch screen optional 




Technical Specifications

Ordering Information

ECGInput dynamic range±0.5mVp~±5mVp
HR measuring range15bpm~350bpm
HR measuring accuracy±1% or ±2bpm, whichever is greater
Sensitivity selection×1/4, ×1/2, ×1, ×2, ×4 and Auto
Sweeping speed6.25, 12.5, 25, 50mm/s
Common-mode rejection ratio (CMRR)≥105dB (Monitoring mode)
≥89dB (Diagnostic mode)
NIBPTechniqueOscillometric
Typical measurement time<30 seconds (typical adult cuff)
Measuring range
Systolic pressureAdult: 40mmHg~275mmHg
Pediatric: 40mmHg~200mmHg
Neonate: 40mmHg~135mmHg
Diastolic pressureAdult: 10mmHg~210mmHg
Pediatric: 10mmHg~150mmHg
Neonate: 10mmHg~95mmHg
Mean arterial pressureAdult: 20mmHg~230mmHg
Pediatric: 20mmHg~165mmHg
Neonate: 20mmHg~110mmHg
Measurement accuracyMaximum mean difference: ±5 mmHg
Maximum standard deviation: 8 mmHg
Measurement modeManual, Auto, STAT
Automatic measuring intervals1~480min
TemperatureMeasuring range21.0°C~50.0°C
Measuring accuracy±0.2°C for range from 25.0°C~45.0°C
Respiration RateMeasuring range0rpm~120rpm
Measuring accuracy±5% or ±2rpm, whichever is greater
SpO2SpO2 measuring range0%~100%
SpO2 measuring accuracy2% for range from 70% to 100%
PR measuring rangeLow perfusion performance As low as 0.4%
PR measuring accuracy0bpm~250bpm
EtCO2(Optional)Measuring accuracy0mmHg ~ 150mmHg
Measuring range±2bpm or ±2%, whichever is greater
Dual IBP(Optional)Measuring accuracy-30mmHg ~ 300mmHg
Measuring range±4mmHg or ±2%, whichever is greater
Cardiac Output(Opional)Measuring range0.2 ~ 20l/min
Measuring accuracy0.2l/min or 10%, whichever is greater
Blood Temperature(BT)23°C ~ 45°C
Injector Temperature(IT)0°C ~ 20°C
Cerebral State Monitoring(Optional)Measuring range
Cerebral State Index(CSI)0~100
Burst SuppressionRatio(BS%)0~100%
Forehead EMG Ratio(EMG%)0~100%
Measuring accuracy±2 or ±10%, whichever is greater
OthersPower supply100~240Vac, 50/60Hz
Built-in lithium battery4400mAh Lithium battery
Display12.1 inch TFT touch screen
Alarming methodAudible-visual alarm
Networking portEthernet port


Catalogue No.Superview-12


Provide Comprehensive Solution For
Global Patients
Fill out the form to leave inquiries. We would get back to you as soon as possible.